FENDER PERFORMANCE TEST - PANEL ACCOUNT - FENDER RUBBER TSE K 46 NORM
FENDER PERFORMANCE TEST - PANEL ACCOUNT - FENDER RUBBER TSE K 46 NORM
FENDER PERFORMANCE TEST
Fenders are generally tested according to PIANC 2002 guidelines.
The fenders are tested under a special press, vertically and under pressure.
According to the principles of PIANC 2002, the pressure loading rate is between 2 - 8 cm per minute and the test ambient temperature should be 23°C ± 5C.
The peculiarity of doing this test: The reaction force of the fender, minimum and maximum
is to find the damping (Absorption) value. Compression at design value
( deflection ) rate is recorded at 5% intervals and then its absorption is calculated.
The tolerance in the performance value is ± 10%.
With this test performed on the basis of PIANC 2002, it is to find the absorption power of the fender that can resist the kinetic energy of the ship during berthing.
That is, kinetic energy ( joule) = Absorption power. ( N-m ) The factor of safety is excluded. The coefficient is evaluated according to the berthing position of the ship.
In parallel berthing, the calculation is made as if the ship is berthing to the 2nd fender. For bow-to-land connections, a fender must be able to absorb the kinetic energy of the ship.
The safety coefficient is taken as 1.25 - 1.5
Our company can perform all these tests. If necessary, we do it under the supervision of Loyd and you.
Kinetic energy the berthing energy of the ship = M . V 2 / 2 = Joule = ( N-m )
M= Weight of the ship when full ( kg )
V = Ship's berthing speed ( m/s )
This energy response is the absorb energy. N-m
FENDER PERFORMANCE TEST WITH LOADCELL
We test the fenders and other products we produce according to the principles of PIANC 2002.
If desired, we can also test with you.


PANEL HESABI - PANEL ACCOUNT

P : Gövde basıncı - Hull pressures
R : Usturmaça reaksiyon kuvveti - Fender reaction force
W : Panel genişliği - Panel width
H : Panel yüksekliği - Panel height
Seçilen panel genişliği - Chosen panel width : 2 metre
Seçilen panel yüksekliği - Chosen panel height : 3 metre
Enerji sönümleme kapasitesi - Energy absorption capacity : 412,5 kN-m
Reaksiyon kuvveti - Reaction force : 1746 kN
Panele m² gelen kuvvet 1m² maksimum - The maximum force per m² on the panel is 1m² : < 200 - 300 kN/m² ~ 20 ile - and 30 Ton/m²

P = 5,82m² Hesaplanan panel alanı,bu alanı 6m² olarak alabiliriz - The calculated panel area can be taken as 6m²
Panelin 1m² gelen kuvvet - The force applied to 1m² of the panel = 1746 kN ÷ 6/m² = 291 kN/m²
Bu değerde - At this value < 300,00 kN/m² den küçüktür - is smaller than
Hesaplanan değerlere göre emniyet katsayısının altında çıkmaktadır - According to the calculated values, it is below the safety factor


